| FEATURES |
SPECIFICATIONS |
| Dimension: |
Height: 156 cm, Depth: 55cm, Width: 61 cm. /
Weight: 70 kg |
| Construction: |
MS Tubular, rigid, electrostatically powder-coated paint. |
| Cylinder Yoke: |
Gas specific, pin indexed yokes with sliding stainless steel clamping bars for easy handling. |
| Pressure
Gauges: |
Large diameter (63mm) - two each for Oxygen and Nitrous Oxide, fitted at a convenient angle for better visibility and clarity (colour coded) |
| Regulators: |
Redesigned for higher efficiency and reliability, two each for Oxygen and Nitrous Oxide. |
| Rotameters: |
Long (230mm) rotating bobbin flowmeters calibrated in double scale for accuracy and clarity in reading (available for 2 gas systems)
Oxygen : lOLt/min; Nitrous Oxide : 12Lt/min; |
| Non return cum: |
Minimises risk of backflow of gases, blows off when pressure exceeds 200cm to 250cm H2O of pressure relief valve water column. |
| OFWD: |
There will be an audible alarm & visual if the supply of Oxygen fails from the Oxygen cylinder or the pipeline. |
| Vaporisers
: |
One plenum type Goldman vaporiser supplied as standard, with space for one more vaporiser Tec Halothane vaporiser (optional). Flow with temperature-compensated Halothane vaporiser. |
| Table Top (Top Tray): |
MS (597mm x 360mm; Rigid top tray for monitors; load capacity 22kg |
| Gas Outlets: |
Two oxygen gas outlets (pressure 4.22 kg/cm2; space for optional ventilator. |
| Provision for Circle Absorber: |
Circle Absorber fitted with machine at extra cost (optional) |
| Provision for B type cylinder: |
Extended rear platform for two 10 Lt water capacity cylinders. |
| Mobility: |
Four large diameters anti static S.S. castor wheels with bearings. Front castors have breaks and rear without break. |
| Breathing
Attachment : |
Standard Magill's circuit with changeover unit open to closed circuit (and vice versa) and emergency Oxygen switch.
|
| General Description: |
Anesthesia Apparatus Boyle-Basic (Actova) design has been made by Azex. It is being used in India for more than 40 years. The anesthesia apparatus Boyle-Basic (Actova) frame is made of rigid tubular steel with special electrostatic powder-coating, large antistatic castor wheels fitted with front brakes for easy mobility and stability. Long tube rotating bobbin rotameters, calibrated in double scale offer accuracy and clarity in reading |
| Safety: |
Oxygen failure warning device • Interlocked Oxygen/Nitrous Oxide supply • Down stream receipt of oxygen • Blow off valve • Anti hypoxic Guard (optional) |